Bộ lập trình PLC Kinco KS105-16DT (8*DI, 8*DO,1*RS232, 1*RS485)

MCTT Việt Nam

Thành viên
Tham gia
13/7/2021
Bài viết
12
Bộ lập trình PLC Kinco KS105-16DT (8*DI, 8*DO,1*RS232, 1*RS485)

Tính năng
  • Significant savings in installation space:
Thin plate compact design, thickness less than 25mm, can be installed in a small electrical cabinet.
  • Higher computing speed:
Adopt new MCU platform, 1000 bit instruction scan cycle is 0.25ms, can reach the same kind of small PLC first-class level.
  • Built-in CANopen interface:
KS105C1 and KS105C2 built-in CAN interface, which supports CANopen master station and slave station and CAN free protocol. With convenient motion control instruction library, it provides more cost-effective choice for multi-axis application occasions.
  • 4-channel high-speed pulse counter:
Provide 4-channel high speed pulse counter with maximum counting frequency of 200K. Each high-speed counter allows up to 32 PV values to be configured and supports 32 CV=PV interrupts. High-speed counter support a variety of modes, can be carried out single phase, double phase (Up/Down), AB phase (1 times frequency and 4 times frequency) count. Users can use the HSC configuration wizard in the programming software to configure visually.
  • 4-channel high-speed pulse output:
Provide 4-channel high-speed pulse output, both support PTO (pulse train) and PWM (pulse width modulation) mode output. Three of channels output frequency up to 200 KHz (load resistance is not greater than 1.5 K Ω), the other one output frequency is 10KHz;The software provides PLS (PWM or PTO) positioning control instruction group PFLO_F (follow instruction) and so on, which facilitates the user to realize simple motion control application.
  • Serial ports of communication:
Provide 1 RS232 and 1 RS485 Serial ports, Named PORT0 and PORT1 respectively, the highest communication baud rate is 115.2Kbps;PORT0 can be used as a programming port, and also supports Modbus RTU slave station protocol and free communication. PORT1 can be used as both programming port and Modbus RTU master station slave station protocol and free communication.
  • Extension modules are available as Modbus slaves:
The RS485 interface of the extended module can be used as a Modbus slave station to provide more cost-effective solutions for more applications.

Link sản phẩm: https://mctt.vn/ks105-16dt

1695347141915.png

1695347167128.png
 
×
Quay lại
Top